Hazardous Materials, CBRN and Energy Hazards Program
Document FSSMS-PRG-11Stage 1Revision 4Version 0.3.3
Topic pages open on your jurisdiction, and requirements tables show its line. You can change this on any page.
This program is the written, auditable system for protecting members at incidents involving hazardous materials, deliberate chemical, biological, radiological and nuclear (CBRN) releases, illicit drugs and clandestine laboratories, and the energy hazards that have arrived in every district in the last decade: lithium-ion batteries in vehicles, homes and buildings, stationary energy storage systems, solar photovoltaic arrays and hydrogen. When this program is working, the department has declared in writing what level of hazmat service it provides and trained and equipped every member to that level and no further; nobody enters an unknown atmosphere without monitoring it, and nobody treats battery off-gas as anything but immediately dangerous to life or health; members leave every hazmat and battery incident through a decontamination corridor and their exposure is on a record that will still exist in 30 years; a member who finds a powder at an overdose call puts on gloves, keeps their hands away from their face, treats the patient, and is neither panicked nor careless; a crew at an electric vehicle fire identifies the vehicle, shuts it down, cools the battery or lets it burn out under watch, and escorts it to a yard where the tow operator has been warned; and no member has ever been told to overhaul a damaged battery system. The department can show every one of those with records.
Module switch: Required at the awareness and operations level for every department, because every suppression company will meet a hazmat release, an overdose scene, a battery fire or a solar roof. The technician sub-module applies only where the department provides a hazmat technician team; otherwise the department records its mutual aid or provincial team arrangement and keeps the awareness, operations and mission-specific elements.
Profile Worksheet question answered: 01 Program Profile Worksheet Part C, module 13 (Hazardous Materials, CBRN and Energy Hazards), and Part B (medical first response level, which sets the opioid and infection control scope).
- Action level: an instrument reading at which a defined action is taken (leave, ventilate, upgrade PPE, no entry); set by the department from the occupational exposure limits and medical direction, not read from the meter’s factory alarm.
- APIE: the hazmat incident management process: analyze the problem, plan the response, implement the plan, evaluate the progress (NFPA 470, 2022).
- Awareness level: the competency of a person likely to witness or discover a hazmat release and expected to recognize it, isolate, deny entry and call for help (NFPA 470, 2022).
- CBRN: chemical, biological, radiological and nuclear agents released deliberately; the term the Canadian first-responder PPE standard uses (CSA Z1610-11).
- Decontamination corridor: the marked path from the hot zone through the warm zone in which contamination is removed from people and equipment before they enter the cold zone.
- Energy storage system (ESS): a stationary installation of batteries or other devices that stores electrical energy, from a residential wall unit to a container at a utility site (NFPA 855, 2026).
- IDLH: an atmosphere immediately dangerous to life or health; battery off-gas is treated as IDLH (MLITSD, n.d., GN 6-50).
- Operations level: the competency of a responder who takes defensive action at a release from a safe distance, with mission-specific competencies added by the department (NFPA 470, 2022).
- Psychological safety: the shared belief that it is safe to speak up, ask, admit error and challenge a decision (Edmondson, 1999)DOI.
- Stranded energy: the electrical energy left in a damaged battery that cannot be discharged by normal means and can cause reignition or shock long after the fire (NTSB, 2020, SR-20/01).
- Technician level: the competency of a responder who takes offensive action to control a release, in chemical protective clothing where required (NFPA 470, 2022).
- Thermal runaway: the self-sustaining, heat-producing reaction inside a lithium-ion cell that spreads to neighbouring cells and produces flammable and toxic gas (NTSB, 2020, SR-20/01).
- WHMIS: the Workplace Hazardous Materials Information System, Canada’s hazard communication system for workplace chemicals, aligned since 2015 with the Globally Harmonized System (Hazardous Products Act [CA], 1985; Hazardous Products Regulations [CA], 2026).
- Work-as-done: how a task is actually performed under real conditions (Hollnagel, 2014).
| Requirement | Source | Stage |
|---|---|---|
| Competency levels for hazmat and WMD responders: awareness, operations, operations mission-specific, technician, incident commander, hazmat officer, hazmat safety officer, EMS | NFPA 470 (2022) | S1 (awareness and operations), S2 (mission-specific, officer), technician where provided |
| Chemical protective clothing selected by a documented risk assessment; ensembles to the hazmat and CBRN ensemble standard | NFPA 1550 (2024, s. 9.6); NFPA 1990 (2022) | S1 |
| Selection, use and care of PPE for first responders to deliberate CBRN events | CSA Z1610-11 | S2 |
| Selection, care and maintenance of hazmat ensembles | NFPA 1891 (2022) | S2 |
| SCBA for any IDLH, potentially IDLH, undefined or hazardous atmosphere, including overhaul | NFPA 1550 (2024, s. 9.11.7) | S1 |
| Respiratory protection program; fit testing; breathing air quality | CSA Z94.4-18; CSA Z180.1:19; the applicable respiratory protection regulation (J14 Respiratory Protection, Fit Testing and Breathing Air); Respiratory Protection Program | S1 |
| Medical surveillance for hazmat team members: baseline, periodic, post-exposure and exit evaluations | NFPA 1580 (2025) | S2 (technician) |
| Exposure records kept for the career plus 30 years | OSHA (n.d.-a) as the benchmark; the applicable records retention rule (J09 Records Retention) | S1 |
| Workplace hazardous products: inventory, SDS, labels, education and training | Hazardous Products Act [CA] (1985) and Hazardous Products Regulations [CA] (2026); the applicable workplace WHMIS regulation (J21 WHMIS, Hazardous Materials and Asbestos); Policy - Hazardous Materials and WHMIS | S1 |
| Transportation of dangerous goods identification, emergency response assistance plans, CANUTEC, Emergency Response Guidebook | Transport Canada (2024); Transportation of Dangerous Goods Act, 1992 [CA] (1992) and Transportation of Dangerous Goods Regulations [CA] (2026) | S1 |
| Opioid exposure precautions for first responders | CCOHS (2018); Health Canada (n.d.) | S1 |
| Installation of stationary energy storage systems, including the emergency response plan the site owner must prepare | NFPA 855 (2026) | S2 |
| Hydrogen technologies | NFPA 2 (2023) | S2 |
| Lithium-ion, EV and ESS response practice | NTSB (2020, SR-20/01); IAFF et al. (2023); MLITSD (n.d., GN 6-19, 6-50 and 6-53) | S1 |
| Workplace electrical safety for shops, charging infrastructure and electric apparatus | CSA Z462:24 | S2 |
| Employer’s duty to take every reasonable precaution; supervisor duties; right to refuse | The applicable OHS statute (J02 Duties of Employers, Supervisors, Workers and Contractors; J07 Right to Refuse and Reprisal Protection); Criminal Code [CA] (1985, s. 217.1) | S1 |
| Accreditation criteria this program answers: deployment objectives for each type and magnitude of hazmat incident; compliance with hazmat regulation including annual refresher training, medical monitoring, physical examinations and exposure record retention; an annual documented appraisal of the hazmat program; a comprehensive contamination control program; exposure records kept to law and current research; procedures to reduce exposure to harmful chemicals with an improvement process | CPSE (2019, criteria 5H.1, 5H.2, 5H.3, 11A.4, 11A.9 and 11A.10) | S2 |
R = responsible, A = accountable (one per row), C = consulted, I = informed.
| Element | Fire chief | Deputy chief, operations | Program manager (Hazardous Materials team) | Incident commander | Hazmat officer / hazmat safety officer | Company officer | Member | HSO | Department physician | JOHSC |
|---|---|---|---|---|---|---|---|---|---|---|
| Service level declared and resourced | A | R | R | C | C | C | ||||
| Program content, SOGs, pre-plans | I | A | R | C | C | C | C | C | C | |
| Risk management at a hazmat or energy incident | I | I | I | A | R | R | R | I | ||
| PPE selection at an incident | I | I | I | A | R | R | R | C | ||
| Air monitoring program (instruments, calibration, action levels) | I | I | A | R | R | R | C | C | C | |
| Decontamination at incidents | I | I | I | A | R | R | R | C | ||
| Exposure records and medical surveillance | I | I | C | R | R | A | R | C | ||
| WHMIS in stations and shops | I | A | C | R | R | R | C | |||
| Training and competency verification | I | A | R | C | R | R | C | I | ||
| Answering a member’s concern | I | I | A | R | R | C | ||||
| Indicators, quarterly update, annual appraisal | I | A | R | C | I |
Generic duties: 01 Roles and Responsibilities. Team structure: 06 Program Improvement Teams.
Requirement. The department declares in writing the hazmat and CBRN service level it provides, maps it to the competency levels of NFPA 470, trains and equips every member to the declared level, and does not send members beyond it (NFPA 470, 2022; MLITSD, n.d., GN 6-9).
The levels and what the baseline department needs.
| Level | Who | What they can do | Baseline department |
|---|---|---|---|
| Awareness | Every member, including non-operational staff who may discover a release | Recognize, isolate, deny entry, identify from a distance, call for help | Required for all |
| Operations | Every suppression member | Defensive actions from outside the hot zone: isolation, scene control, protective actions for the public, product identification, emergency decontamination | Required for all suppression members |
| Operations mission-specific | Suppression companies the department selects | PPE use, technical decontamination, mass decontamination, air monitoring and sampling, product control (diking, damming, plugging), evidence preservation, illicit laboratory response, radiological tasks, as the department chooses | Required: PPE, air monitoring, technical and mass decon, evidence preservation, illicit lab awareness; others by district risk |
| Technician | Hazmat team members | Offensive control of a release in chemical protective clothing; sampling and identification; specialty tasks (tank car, cargo tank, intermodal, flammable liquids and gases bulk, radioactive materials, as trained) | Only where the department provides a technician team; otherwise the regional or provincial team by written agreement |
| Hazmat incident commander | Chief officers who command hazmat incidents | Command of a hazmat incident within the IMS | Required for every chief officer who may command one |
| Hazmat officer | Technician team officers | Manages the hazmat group under the incident commander | Where a technician team exists |
| Hazmat safety officer | Qualified members | Safety function for the hazmat group, reporting to the ISO or the incident commander | Where a technician team exists; otherwise the ISO with hazmat operations training |
| EMS at hazmat incidents (BLS, ALS) | Medical first responders | Patient care at hazmat incidents | At the department’s medical first response level |
Minimum method. A one-page service level statement signed by the fire chief; the competency map in the training matrix (section 6); written mutual aid and provincial team call-out arrangements with contact numbers on every apparatus; dispatch screening questions for battery, EV, ESS, solar, gas and unknown-substance calls.
Evidence. Service level statement; training records by level; agreements; dispatch question card. Stage: S1.
Requirement. Every hazmat incident is managed by the APIE process inside the incident management system, with hazard control zones, air monitoring, PPE selection by risk assessment, decontamination before anyone leaves the warm zone, and a termination and debrief (NFPA 470, 2022; NFPA 1550, 2024, ch. 10).
Minimum method.
- Isolate and identify from a distance. Upwind, uphill, upstream. Use placards, labels, shipping documents, SDS, the Emergency Response Guidebook, CANUTEC and the shipper’s emergency response assistance plan (Transport Canada, 2024). Deny entry. Initial isolation and protective action distances from the Guidebook until the product is identified.
- Zones. Hot (the release and the area where the hazard exists), warm (the decontamination corridor and the entry control point), cold (command, staging, rehab, medical). Entry control at the warm-zone boundary records every member in and out (see Form - Hazmat Entry Log and Air Monitoring Record).
- Air monitoring before and continuously. Section 5.4.
- PPE by hazard. Section 5.3. SCBA is the default in any unknown atmosphere (NFPA 1550, 2024, s. 9.11.7).
- Entry and backup. No entry team without a backup team of equal number in the same level of PPE, ready at the entry point. Buddy rule inside. Medical monitoring before entry and after exit (section 5.6).
- Decontamination. Section 5.5. Emergency decon is set up before the first entry, even when the plan is defensive, because a contaminated member or a contaminated civilian will not wait.
- CBRN and criminal scenes. Police lead the criminal investigation; the fire department leads life safety and hazard control; evidence is preserved as the mission-specific competency teaches; unified command from the start.
- Termination and debrief. Accountability closed; exposures recorded; equipment decontaminated or bagged; hot debrief; exposure reports filed before end of shift.
Evidence. Incident records; entry logs; monitoring records; exposure reports; debrief cards. Stage: S1.
Requirement. Chemical protective clothing is selected by a documented risk assessment, meets the hazmat and CBRN ensemble standard, is inspected and tested on schedule, and is matched to the member’s training (NFPA 1550, 2024, s. 9.6; NFPA 1990, 2022).
Minimum method. The NFPA 1990 (2022) classes replaced the vapour-protective, liquid-splash and CBRN standards with one scheme (NFPA 1990, 2022); the department keeps a selection matrix by class against the hazards in its risk profile, and for deliberate CBRN events uses the selection, use and care guidance in the Canadian first-responder standard (CSA Z1610-11). Structural firefighting PPE is not chemical protective clothing and is never used as such; it is accepted for defensive operations outside the hot zone and for the energy-hazard incidents in section 5.9 with SCBA. Ensembles are inventoried by lot and expiry, stored to the manufacturer’s instructions, inspected after every use and at least annually, and vapour-protective suits are pressure tested to the manufacturer’s schedule, at least annually and after use (NFPA 1891, 2022).
Evidence. Selection matrix; inventory with expiry; inspection and pressure test records. Stage: S1 (matrix for the declared level), S2 (full care and maintenance records).
Requirement. No member enters an atmosphere that may be hazardous without monitoring it first, and monitoring continues while they are in it. The department sets written action levels, trains members on the instruments they carry, and keeps the instruments bumped and calibrated (MLITSD, n.d., GN 6-51).
Instruments. Every first-due suppression company carries a four-gas instrument (oxygen, lower explosive limit, carbon monoxide, hydrogen sulphide); companies with the air monitoring mission-specific competency add a dedicated hydrogen cyanide sensor (the fire-gas “toxic twin” with carbon monoxide, which the standard four-gas instrument does not measure), a photoionization detector for volatile organic compounds, and radiation detection; the technician team adds the colorimetric, pH and specialty instruments its service level requires.
Action levels (department defaults; confirm against the occupational exposure limits your jurisdiction adopts (J22 Exposure Limits, Heat and Cold Stress) and the department’s medical direction). The research gives these commonly used fire-service values: oxygen outside 19.5 to 23.5 per cent; flammable gas at or above 10 per cent of the lower explosive limit (leave and ventilate), with 20 per cent as “no entry”; carbon monoxide at or above 25 to 35 ppm; hydrogen cyanide at or above 4.7 ppm; hydrogen sulphide at or above 10 ppm; any reading on a radiation instrument above background that the department’s radiological procedure defines (MLITSD, n.d., GN 6-51). At any of these, SCBA stays on, the member leaves or does not enter, and command is told. Readings are used to decide when filtering respirators may be used for exterior or secondary tasks, to protect investigators and support staff, and to document exposures; they are never an “all clear” for interior overhaul, where SCBA is mandatory regardless (see Respiratory Protection Program).
Where to monitor. Before entry; continuously during entry; at the decontamination corridor; in the rehab area; during overhaul; at the perimeter of a battery or ESS incident for hours after knockdown; in any below-grade or enclosed space.
Care. Bump test before each use or daily on the apparatus; calibrate at the manufacturer’s interval and at most every 30 days, and after any exposure that could have damaged a sensor; track sensor life; record every bump, calibration and failed test (MLITSD, n.d., GN 6-51).
Evidence. Instrument inventory; bump and calibration logs; monitoring records with each incident; training records per instrument. Stage: S1 (four-gas on every first-due company, action levels written), S2 (full instrument set and records).
Requirement. Every member and every piece of equipment that enters a hot zone passes through decontamination before it enters the cold zone, and every contaminated civilian is decontaminated before transport (NFPA 470, 2022).
Three kinds.
- Emergency decontamination: immediate gross removal of contaminant from a person whose life or health is threatened, with copious water, before anything else is set up; clothing removed as needed. Set up at every hazmat and energy incident before the first entry.
- Technical decontamination: the corridor (toolkit item 4) for entry teams in chemical protective clothing: tool drop, gross wash, suit wash and rinse, suit removal, SCBA removal, inner glove and clothing removal, personal wash, medical check. Staffed by members in PPE one level below the entry team or as the risk assessment sets.
- Mass decontamination: large numbers of civilians, using apparatus and hose lines in a corridor, with privacy, warmth and a process for clothing and valuables; planned in advance for target hazards.
Link. The hierarchy of contamination control, on-scene preliminary exposure reduction after fires, clean cab transport, post-call station decontamination and the shower-within-the-hour rule are in Decontamination and Contamination Control Program. A hazmat incident ends with that program’s post-call steps as well as the corridor.
Evidence. Corridor setup checklist completed at every entry incident; decon equipment inspection; mass decon pre-plans; photos or diagrams from drills. Stage: S1 (emergency and basic technical decon), S2 (mass decon pre-plans).
Requirement. Every exposure or suspected exposure to a hazardous material, a battery gas, a drug or a radiological source is recorded against the member, kept for the length of the career plus 30 years, and available to the member and the physician. Hazmat technicians are under a medical surveillance program with baseline, periodic, post-exposure and exit evaluations (NFPA 1580, 2025).
Minimum method. The exposure report in SWP - Exposure Reporting is filed before the end of the shift for every member who was in the warm or hot zone, with the substance, duration, route, PPE, monitoring readings, decontamination done and any symptoms; the HSO keeps the exposure register; records feed the presumptive illness documentation in Occupational Cancer Prevention, Exposure Tracking and Screening Program. Technician medical surveillance is set with the department physician under Medical, Fitness and Wellness Program: a baseline before team assignment, a periodic evaluation at the interval the physician sets (annually or every two years), an evaluation after any significant exposure or symptoms, and an exit evaluation on leaving the team. Medical records stay with the physician and are confidential; the exposure register and the medical record are linked by the member’s identifier, not merged.
Evidence. Exposure register; retention schedule in 05 Document Control and Records; physician’s confirmation that the surveillance program exists and who is on it. Stage: S1 (exposure records), S2 (technician surveillance).
TDG. Members at the awareness level recognize the TDG placards, labels and shipping documents; the Emergency Response Guidebook is on every apparatus in current edition; CANUTEC’s number is on every apparatus; the pre-plans identify the rail, highway, pipeline and marine corridors and the fixed facilities in the district, with the shipper’s emergency response assistance plan contacts where they exist (Transport Canada, 2024; Transportation of Dangerous Goods Act, 1992 [CA], 1992; Transportation of Dangerous Goods Regulations [CA], 2026).
WHMIS. Hazardous products in stations, shops and on apparatus (fuels, foam concentrates, cleaning agents, batteries, compressed gases) are inventoried, matched to a current safety data sheet available on every shift, labelled including when decanted, stored and handled as the SDS directs, and every member has general WHMIS education and workplace-specific training reviewed annually with the JOHSC. Supplier labels and safety data sheets follow the federal rules (Hazardous Products Act [CA], 1985; Hazardous Products Regulations [CA], 2026); the workplace side, including the training review, is set by the applicable WHMIS regulation, and most require at least an annual review (J21 WHMIS, Hazardous Materials and Asbestos). This element is the department’s WHMIS and hazard communication program; the policy is Policy - Hazardous Materials and WHMIS.
Evidence. ERG edition on apparatus; corridor pre-plans; WHMIS inventory matched to SDS; training records. Stage: S1.
Requirement. Members at overdose scenes, drug seizures and clandestine laboratories are protected against inhalation, mucous membrane and ingestion exposure to opioids and other drugs, without delaying patient care or over-dressing for a hazard that is usually small (CCOHS, 2018; Health Canada, n.d.).
Tiers and PPE (CCOHS, 2018).
| Tier | What is seen | PPE | Notes |
|---|---|---|---|
| Minimal | No visible product; a patient with suspected overdose | Nitrile gloves; eye protection as for any patient contact; no hand-to-face contact | Most overdose-scene encounters present no significant exposure threat (Health Canada, n.d.); treat the patient |
| Low | Small visible quantities of tablets or powder (under about 1 g) | Nitrile gloves (doubled if handling), eye protection, fit-tested N95 or better if powder could become airborne; a second member present | Do not handle more than needed; do not disturb powder |
| Moderate | Street-level quantities or more; visible powder on surfaces; powder being disturbed | Doubled nitrile gloves, coveralls or disposable gown, fit-tested N95 or air-purifying respirator with P100, eye protection, second member; consider SCBA where powder is airborne in an enclosed space | Withdraw and call for the hazmat team or police; do not clean up |
Procedure essentials. Gloves on before contact; hands away from the face; no eating, drinking or smoking; naloxone carried and given for signs of opioid toxicity, with repeat doses possible and EHS called (CCOHS, 2018); decontaminate skin with soap and water, never with alcohol hand sanitizer or bleach, which can increase absorption (CCOHS, 2018); bag contaminated clothing; exposure report filed. Mental health and behaviour-change symptoms after a call are reported and the member is not left alone.
Clandestine laboratories. Do not enter except for a rescue; do not operate switches, lights or equipment; test the air before any entry; assume booby traps; treat as a crime scene under police lead; withdraw and isolate (MLITSD, n.d., GN 6-17).
Evidence. SOG; naloxone inventory with expiry and temperature log; training records; exposure reports. Stage: S1.
Requirement. Members recognize a lithium-ion battery incident, treat the gases as IDLH, control the fire without penetrating the battery, never overhaul a damaged battery system, and hand the hazard over to someone who knows it is still there (NTSB, 2020, SR-20/01; IAFF et al., 2023; MLITSD, n.d., GN 6-19, 6-50 and 6-53).
What the evidence says.
- A lithium-ion cell in thermal runaway produces heat and a mix of flammable and toxic gases (hydrogen, carbon monoxide, hydrogen fluoride, hydrogen chloride and volatile organics are reported); runaway spreads cell to cell and can reignite hours, days or weeks after the fire appears out, because of stranded energy (NTSB, 2020, SR-20/01; MLITSD, n.d., GN 6-50).
- Battery gases accumulating in a garage, a room or a container can deflagrate; the volume of gas depends on the chemistry, and an entry or a ventilation decision made without that in mind has injured responders in research mock-ups and incidents (IAFF et al., 2023).
- At an EV fire, the vehicle fire and the battery fire are different problems: extinguish the cabin and the ordinary vehicle fire, then confine the battery and either cool it directly with a large, sustained water supply or let it burn out under watch; manufacturers’ emergency response guides have been found inadequate and a clear area of about 15 m (50 ft) is recommended at tow and storage yards, though often not achievable (NTSB, 2020, SR-20/01; FSRI, n.d.-a).
Minimum method (the SOG content; full steps in SWP - EV and Lithium Battery Fire and SWP - Solar PV and Energy Storage Systems).
- Dispatch screening. Questions on the call-taker card: is a vehicle, scooter, e-bike, power tool battery, home battery or solar system involved; is it inside a building; is it charging.
- Identify, shut down, watch. Identify the energy system from badges, charging ports, placards, the ISO 17840 rescue sheet where the vehicle carries one, the site’s NFPA 855 emergency response plan or the building owner (NTSB, 2020, SR-20/01). Shut down: vehicle in park, off, chocked, high-voltage disconnect where trained; building rapid shutdown or disconnect; ESS emergency stop; isolate charging. Watch: thermal imager on the battery continuously; air monitoring at the perimeter; a watch period of hours before handover, and a written warning of reignition risk to whoever takes it.
- Full PPE and SCBA for every member near the battery, including after knockdown; off-gas is IDLH (MLITSD, n.d., GN 6-50).
- Defensive unless there is a life hazard at an ESS or a battery fire inside a structure; nobody enters a gas-filled room or container; the ventilation decision is made on the deflagration risk, not by habit (IAFF et al., 2023; MLITSD, n.d., GN 6-53).
- Water supply. Plan for a large, sustained flow to cool a battery pack directly, or a decision to let it burn out with exposures protected. No penetration of the pack, no purchase points through the battery during extrication, a charged line at every EV extrication.
- No overhaul of a damaged ESS or battery pack. Ever (MLITSD, n.d., GN 6-53).
- Damaged batteries inside buildings are removed to the exterior by the method the SOG sets, isolated from combustibles, never carried in an elevator, and monitored (MLITSD, n.d., GN 6-50).
- Tow-yard escort and reignition. An apparatus escorts the EV to the recovery location; the tow operator is told in writing of the stranded-energy and reignition risk; the yard is asked to park it with the recommended clear distance from other vehicles and structures, or the best achievable; the department records the handover (NTSB, 2020, SR-20/01).
- Storage distances and site plans. For ESS sites, the emergency response plan the installation standard requires of the owner is collected into the pre-plan and CAD, with system chemistry, capacity, disconnects, suppression and ventilation, and the owner’s technical contact (NFPA 855, 2026). The installation standard sets capacity thresholds for its scope and for aggregate quantities per fire area; record the ones that apply to each site (NFPA 855, 2026).
- Disposal. A written arrangement with the municipality or a contractor for damaged battery removal and storage; damaged batteries are not brought to the station.
Evidence. SOGs; dispatch card; ESS pre-plans; handover records; training records. Stage: S1 (SOG, dispatch card, PPE rule, no-overhaul rule, escort and handover), S2 (ESS pre-plans, disposal arrangement).
Requirement. Members treat every photovoltaic array as energized in any light, including artificial light and moonlight, and never cut, walk on or remove modules (MLITSD, n.d., GN 6-34).
Minimum method. Identify arrays on size-up and in pre-plans; use the rapid shutdown where installed and know that it isolates the conductors from the array to the inverter, not the array itself; the utility isolates the AC side; apply water to energized equipment only as a fog stream from at least 10 m and never a straight stream; respect roof loading and the loss of ventilation area; ladders and aerials observe the limits of approach for energized conductors (section 5.12); overhaul around arrays is done with the array treated as live. Battery storage paired with the array is an ESS under section 5.9.
Evidence. SOG; pre-plan and CAD flags for arrays; training records. Stage: S1.
Requirement. Members recognize hydrogen fuel-cell vehicles, hydrogen fuelling stations and hydrogen process sites, and apply the hydrogen-specific tactics (NFPA 2, 2023).
Minimum method. Hydrogen burns across a wide range of concentrations (about 4 to 75 per cent in air), ignites with very little energy, burns with a nearly invisible flame and rises; a thermal imager finds the flame. Isolate ignition sources, let a jet fire burn while cooling exposures and the tank from the maximum distance, do not extinguish a leak fire unless the supply can be shut off, and expect a vehicle’s thermal pressure-relief device to vent in a known direction (MLITSD, n.d., GN 6-19). Pre-plan fuelling stations with the operator.
Evidence. SOG; pre-plans; training records. Stage: S2 (S1 where hydrogen infrastructure exists in the district).
Downed power lines, energized vehicles and fences, limits of approach for aerials and ladders near intact lines, natural gas and propane leaks with LEL action levels, and utility coordination are in SWP - Downed Power Lines and Utility Emergencies, owned jointly with Emergency Operations Safety Program. Workplace electrical safety for shops, generators, charging infrastructure and electric apparatus is in Facilities and Station Safety Program under CSA Z462:24.
Requirement. The hazards in sections 5.7 to 5.11 are known before the call. Fixed facilities, TDG corridors, pipelines, marine terminals, ESS sites, solar installations above a size the department sets, EV charging hubs, hydrogen sites and known drug-production locations are pre-planned, flagged in CAD and reviewed on a cycle (NFPA 1660, 2024).
Evidence. Pre-plan coverage; CAD flag counts; review dates. Stage: S2.
Every hazmat entry, every battery or ESS incident, every exposure and every near miss in this program is debriefed at the scene and triaged under Incident Investigation and Learning Program within one business day. Energy-hazard incidents are reviewed by the team at least quarterly because the guidance is changing faster than any other area in this package; the SOGs carry the date of the guidance they rest on and are checked against new guidance at least annually (the guidance notes cited here carried 2026 dates as of October 2026).
(a) Work-as-done. Before the team writes or changes a procedure here, the learning team describes: how a company really decides whether to meter before entering a basement with a “smell of gas”; what happens to the four-gas instrument between calls and who actually bumps it; how members really handle a powder on a kitchen counter at 0200 with a patient not breathing; what the crew does at an EV fire on a highway shoulder with a 1,000 L tank and no hydrant; how a damaged e-bike battery got from a bedroom to the lawn last time; who told the tow operator what, and whether anyone wrote it down; what the decon corridor looks like with six members and one line; how the exposure report really gets filed at the end of a 14-hour night (Hollnagel, 2014; Conklin, 2012).
(b) Capacity and margins. What makes this work go right: a crew that meters by habit, an officer who holds the company outside until the reading is in, a dispatcher who asks the battery question, a thermal imager with a charged battery, a water supply planned before the battery goes, a regional team that answers the phone, a physician who knows the technicians. What erodes it: a single four-gas unit per station that is out for calibration, guidance that changes every few months, volunteers who have never seen an ESS, overdose call volume that makes the powder routine, long waits for the utility, and the pull to “finish the job” on a smouldering pack. The program protects the margin by putting instruments and the dispatch card on every first-due company, by the no-overhaul rule written as absolute, by a quarterly guidance check, by a training night on energy hazards every year at every station, and by making the exposure report a two-minute form that an officer files from the apparatus.
(c) Just culture. A missed meter check, an entry before the backup team was ready, a cleanup of a powder that should have been left, a pack opened during extrication, an exposure report filed late: each is reviewed for the conditions that produced it and what the system must change (Dekker, 2016; Reason, 1997). The learning firewall applies to every debrief, learning team, after-action review and post-incident analysis in this program. Conduct concerns go to a separate process run by different people (Marx, 2001; The Human Factor, 2026a). Filing an exposure report is never held against a member; not filing one is treated as a system problem first.
(d) Psychological safety. Any member may stop a hazmat or energy task by naming the hazard and the action: “Hold the entry, the meter is reading 15 per cent LEL at the door.” The officer acknowledges, acts or says in one sentence why not, and the call is reviewed later. Officers ask the member with the meter what the readings are doing before asking how the task is going. Leaders show it is safe to report by publishing, de-identified, the last exposure report that changed a procedure, and by answering every concern through the route in section 11 within 15 days (Edmondson, 1999)DOI. Members who are anxious after a drug exposure or a battery incident are told that reporting the anxiety is part of the exposure report and that peer support is available without a referral.
(e) Learning link. This program feeds Tier 1 After-Action Review for every hazmat response above awareness and every battery, ESS or solar incident; Tier 2 Post-Incident Analysis for any exposure with symptoms, any entry without a backup team, any battery reignition after handover, any deflagration or any PPE breach; Tier 3 Independent Learning Review for a death, a critical injury or a multi-agency CBRN event (Incident Investigation and Learning Program; method in Manual 02 - The Three Tiers and Event Triage; The Human Factor, 2026a). The AAR questions: What did we know about the product or the energy system before we committed, and when did we know it? What did the meter and the thermal imager tell us, and did we act on them? Who has the hazard now, and do they know?
| Who | What | How often | How verified |
|---|---|---|---|
| Every member | Awareness level: recognition, isolation, identification from a distance, ERG, CANUTEC, calling for help (NFPA 470, 2022) | Recruit, then annually | Written and practical check |
| Every suppression member | Operations level: defensive actions, zones, emergency decon, PPE limits, air monitoring with the four-gas instrument, exposure reporting (NFPA 470, 2022) | Recruit, then annual refresher with a documented practical evolution (MLITSD, n.d., GN 6-9) | Practical evolution sign-off |
| Selected companies | Mission-specific competencies the department chooses (PPE, technical and mass decon, air monitoring and sampling, product control, evidence preservation, illicit lab, radiological) (NFPA 470, 2022) | Initial course, then annual refresher | Competency sign-off per competency |
| Every member | Opioid and drug exposure: tiers, PPE, naloxone, soap-and-water decon, clandestine lab rule (CCOHS, 2018) | Recruit, then annually | Scenario sign-off |
| Every suppression member | Energy hazards: lithium-ion, EV, ESS, solar PV, hydrogen; identify, shut down, watch; no-overhaul rule; escort and handover | Recruit, then annually, with an update whenever guidance changes | Scenario sign-off; dated guidance version recorded |
| Every member who uses an instrument | Instrument-specific operation, bump, calibration, action levels, limits | Initial, then annually | Instrument sign-off (MLITSD, n.d., GN 6-51) |
| Technician team | Technician level and the specialties the service level declares; CBRN PPE selection and use (CSA Z1610-11) | Initial certification; annual refresher; specialty recertification | Certification on file |
| Chief officers | Hazmat incident commander (NFPA 470, 2022) | Before commanding; refresher every three years | Certification |
| Hazmat officer and hazmat safety officer | The officer and safety officer chapters (NFPA 470, 2022) | Initial; refresher every three years | Certification |
| Dispatchers | Screening questions; CANUTEC; utility and regional team contacts | Initial, then annually | Drill record |
| Station and shop staff | WHMIS general education and workplace-specific training | Initial; reviewed annually with the JOHSC (J21 WHMIS, Hazardous Materials and Asbestos) | Training record |
Respiratory protection fit testing and SCBA proficiency are under Respiratory Protection Program.
| Equipment | Check | Interval | Qualified person | Record |
|---|---|---|---|---|
| Four-gas instruments (and HCN, PID, radiation where carried) | Bump test; battery; sensor status | Before each use or daily on the apparatus | Member | Air monitoring log |
| Same | Calibration | Manufacturer’s interval, at most every 30 days, and after a high exposure (MLITSD, n.d., GN 6-51) | Trained member or service provider | Calibration log |
| Radiation instruments and check sources | Calibration; source inventory | Annually | Service provider | Calibration certificate; source register |
| Chemical protective ensembles | Visual inspection; inventory by lot and expiry | After every use; annually | Trained member | Ensemble record |
| Vapour-protective suits | Pressure test | Manufacturer’s schedule, at least annually and after use (NFPA 1891, 2022) | Trained member | Suit test record |
| SCBA | Per the respiratory protection program (flow test, hydrostatic test, air quality) | Per Respiratory Protection Program | SCBA technician | SCBA record |
| Decon corridor equipment (pools, shelters, pumps, brushes, bags, water heater) | Inventory and function | Monthly and after every use | Hazmat or decon company | Decon equipment checklist |
| Naloxone kits | Expiry; temperature exposure; seal | Monthly | Company officer | Medical kit log |
| Emergency Response Guidebook | Current edition on every apparatus | Annually and on each new edition | Company officer | Apparatus inventory |
| Thermal imagers | Function and battery | Daily | Member | Apparatus check sheet |
| Dielectric gloves and non-contact voltage detectors (where carried) | Inspection; electrical test | Per manufacturer; gloves every six months | Service provider | Test record |
| EV and battery response kit (chocks, insulated tools, blankets if adopted, handover warning cards) | Inventory | Monthly | Company officer | Apparatus inventory |
- SWP - Hazmat Entry and Decontamination
- SWP - EV and Lithium Battery Fire
- SWP - Solar PV and Energy Storage Systems
- SWP - Downed Power Lines and Utility Emergencies (joint with Emergency Operations Safety Program)
- Referenced: SWP - Exposure Reporting; SWP - On-Scene Preliminary Exposure Reduction; SWP - Post-Call Station Decontamination; SWP - SCBA Donning, Use and Air Management; SWP - Confined Space Entry and Rescue.
The department’s opioid and clandestine laboratory operating guidelines sit with the medical first response procedures and cite section 5.8.
- Form - Hazmat Entry Log and Air Monitoring Record
- Technician exposure record (toolkit item 3); decon corridor setup checklist (item 4); EV incident checklist (item 5); ESS pre-incident plan template (item 6); quarterly indicator worksheet (item 7); training sign-off (item 8).
- Exposure register and retention schedule in {{Records system}} per 05 Document Control and Records.
- Service level statement; mutual aid and provincial team agreements; pre-plans; instrument logs.
| Indicator | Type | Definition | Baseline measure | Target direction |
|---|---|---|---|---|
| Competency currency by level | Leading | Members current (within 12 months) at the level their assignment requires | Training records | 100% |
| Instrument readiness | Leading | Four-gas instruments on first-due companies with a bump test logged that day, from a monthly sample | First quarter | 100% |
| Monitoring before entry | Leading | Hazmat and energy incidents with a pre-entry reading logged | First quarter | 100% |
| Decon corridor at entry incidents | Leading | Entry incidents with the corridor checklist completed | First quarter | 100% |
| Exposure reports filed | Leading | Members in the warm or hot zone with an exposure report filed before end of shift | First quarter | 100% |
| EV and ESS handover documented | Leading | EV and battery incidents with a written handover warning recorded | First quarter | 100% |
| Energy-hazard training currency | Leading | Suppression members with the annual energy-hazards session in the last 12 months | Training records | 100% |
| Near-miss and good-catch reports in this program (psychological safety) | Leading | Reports per 10 hazmat or energy incidents, with the share acknowledged to the reporter within 15 days | First year | Rising then stable; 100% acknowledged |
| Stop-work and challenge calls (psychological safety) | Leading | Calls made at hazmat or energy incidents, from debrief cards; share reviewed; reprisals | First year | Rising; 100% reviewed; 0 reprisals |
| Members who can raise a concern with their officer (psychological safety) | Leading | Annual culture survey item, hazmat team and suppression companies | First survey | Rising |
| Exposures with symptoms | Lagging | Exposure reports with symptoms, by substance | Last three years | Falling; every one reviewed |
| Battery reignition after handover | Lagging | Reported reignitions at yards or storage after a department handover | First year | Tracked; every one reviewed |
| Regulator or WCB claims related to hazmat exposure | Lagging | Claims per year | Last three years | Tracked |
| Element | Who | How |
|---|---|---|
| Owner | Deputy chief, operations | Accountable for the service level being resourced and met; receives the quarterly update; signs the annual appraisal |
| Doer | Program manager (line officer leading the Hazardous Materials team) with the team lead and members; every incident commander, hazmat officer, company officer and member at incidents; the HSO for the exposure register; the physician for surveillance | Cycle in 06 Program Improvement Teams; elements performed at every incident |
| Verifier | ISO or hazmat safety officer at every entry incident; HSO sample of all hazmat and energy incident records each quarter (monitoring, entry log, decon checklist, exposure reports, handover); JOHSC review of exposure register trends annually; internal audit against Checklist - Hazardous Materials and Energy Hazards | Sample results and audit findings to the quarterly update and the Corrective Action Register |
| Feedback | Quarterly update to the deputy chief, senior team and JOHSC; change notice to every station with every SOG change and with every guidance update; the monthly operations meeting. A member’s concern: raised to the company officer, the team lead, the HSO, the JOHSC consultant or the near-miss system (anonymous accepted); logged by the team lead within two working days; answered to the member within 15 days with the decision and the reason | Concern log with dates raised and answered, in the quarterly update |
| Closure | Corrective Action Register | Every deficiency logged with an owner, a priority from P1 (Imminent) to P4 (Improvement) and the due dates that priority sets (a P1 (Imminent) item the same shift, others within five working days); verified closed with evidence by the HSO or the JOHSC; escalation as the scale sets (a P3 (Moderate) item to the deputy chief at 30 days overdue and the fire chief at 60); closure reported to the JOHSC |
Loop test. A member reports on Monday that the four-gas instrument on the rescue has been reading low oxygen on bump for a week and nobody knows if it has been calibrated. By Wednesday the instrument is out of service with a replacement from the spare pool, the item is in the register with the company officer as owner, the HSO has pulled the calibration logs for every instrument in the district, and the member has been told. Within the month, the gap in the calibration schedule is closed, a change notice goes out, and the quarterly update reports it as closed with the logs as evidence.
Audited against Checklist - Hazardous Materials and Energy Hazards. The five questions an auditor asks first:
- Show me the service level statement and the training records that prove every suppression member is current at the operations level and every technician is certified.
- Pick any first-due apparatus. Show me today’s bump test for its four-gas instrument and its last calibration.
- Show me the last three battery, EV or ESS incidents: the monitoring record, the thermal imager watch, the handover warning and who signed it.
- Show me the exposure register: the last ten entries, how long they are kept, and how a member gets a copy.
- Show me the last concern a member raised about a hazmat or energy procedure and what they were told.
Accreditation crosswalk. This program’s records answer the hazmat program criteria on deployment objectives, regulatory compliance (annual refresher, medical monitoring, examinations, exposure record retention) and the annual appraisal (CPSE, 2019, criteria 5H.1 to 5H.3), the chemical exposure reduction and improvement process (11A.4), the contamination control program (11A.9) and exposure record keeping (11A.10). Hazmat first-responder-only agencies must still answer criterion 5H. The 11th edition applies from 2027; map the numbers again when it issues.
- Members have entered unknown atmospheres (carbon monoxide and hydrogen cyanide during overhaul, hydrogen sulphide at chemical suicides, carbon dioxide in refrigeration and beverage systems) without monitoring; firefighter guidance notes exist because of those events (MLITSD, n.d., GN 6-51). Section 5.4 is the control.
- Structural gear has been used as chemical protection, hoods have come off during overhaul, and decon has been skipped so that contaminated gear rode home in the cab and the exposure was never written down, undermining the member’s later claim (MLITSD, n.d., GN 6-9). Sections 5.3, 5.5 and 5.6 are the controls.
- Opioid scenes have produced both over-dressing that delayed patient care and bare-handed handling of bulk powder (Health Canada, n.d.; CCOHS, 2018). Section 5.8 is the control.
- Electric vehicles have reignited on flatbeds and in storage yards after the fire department left, packs have been punctured during extrication, and responders have entered gas-filled garages and containers before anyone thought about deflagration (NTSB, 2020, SR-20/01; IAFF et al., 2023). Section 5.9 is the control.
- Crews have assumed a utility disconnect de-energized a solar array and have cut conduit on roofs (MLITSD, n.d., GN 6-34). Section 5.10 is the control.
- Clandestine laboratories have exploded when switches were operated (MLITSD, n.d., GN 6-17). Section 5.8 is the control.
- New hazards outrun procedures when nobody owns management of change; the quarterly guidance check in section 5.14 and the team’s cycle are the control.
Stage 1 (Foundation) is: the service level statement signed; awareness training for all and operations training for every suppression member, with the annual practical evolution; a four-gas instrument on every first-due company with written action levels, a bump and calibration log and a trained user on every shift; the hazmat response SOG with zones, entry control, backup team and emergency decon; the opioid procedure with naloxone and soap-and-water decon; the energy-hazards SOGs (EV and lithium-ion, ESS, solar PV) with the dispatch card, the PPE and SCBA rule, the no-overhaul rule and the tow escort and handover; the exposure report filed for every warm or hot zone member and the register kept; the Emergency Response Guidebook and CANUTEC on every apparatus; the regional or provincial team agreement; WHMIS inventory, SDS access and training in every station; the concern route announced.
Stage 1 cost. Instruments: a four-gas unit per first-due company plus spares and a calibration station (capital, plus annual sensors and gas). Training: one night per station for operations refresher, one for energy hazards, one for opioids (instructor time; volunteer time credited). Naloxone kits per apparatus. Handover warning cards and chocks. The program manager’s time, about four hours a month.
Stage 2 (Operating) adds the mission-specific competencies, the full instrument set, the technician medical surveillance program, ESS pre-plans with the owners’ emergency response plans, TDG corridor pre-plans, mass decon plans, ensemble care records, hydrogen pre-plans and the indicators reported quarterly.
Stage 3 (Learning) adds trend analysis of exposures against health outcomes, field trials of battery suppression methods and instruments, published lessons, and external review.
This chapter relies on the following legal requirements, which differ by province and territory. Check your jurisdiction’s section on each topic page before adopting it.
| Topic | What to check in your jurisdiction | Page |
|---|---|---|
| Duties of Employers, Supervisors, Workers and Contractors | The employer’s general duty to take every reasonable precaution and the supervisor’s duties, which carry hazmat and energy-hazard work where no specific rule applies | J02 Duties of Employers, Supervisors, Workers and Contractors |
| Right to Refuse and Reprisal Protection | The member’s right to refuse unsafe work, any limit on it during emergency response, and the protection against reprisal | J07 Right to Refuse and Reprisal Protection |
| Records Retention | How long exposure records must be kept; this program keeps them for the career plus 30 years until your rule is confirmed | J09 Records Retention |
| Firefighter PPE and Protective Equipment | Any rule on firefighter protective equipment, including SCBA built to the NFPA standard and a hood wherever members may meet harmful contaminants | J13 Firefighter PPE and Protective Equipment |
| Respiratory Protection, Fit Testing and Breathing Air | The respirator program standard the regulation adopts (such as CSA Z94.4), the fit-test interval and method, and the breathing air standard | J14 Respiratory Protection, Fit Testing and Breathing Air |
| Confined Space | Whether tank, vault and container entries at hazmat incidents fall under the confined space rules, and any emergency response exemption | J17 Confined Space |
| Lockout, Machine Guarding and Electrical Safety | The limits of approach to energized electrical conductors for equipment, including aerials and ladders | J19 Lockout, Machine Guarding and Electrical Safety |
| WHMIS, Hazardous Materials and Asbestos | The workplace WHMIS regulation (education and training and its review interval, workplace labels, SDS access) and the duty to report a spill or release, and to whom | J21 WHMIS, Hazardous Materials and Asbestos |
| Exposure Limits, Heat and Cold Stress | Which occupational exposure limits apply (an ACGIH edition or the jurisdiction’s own table), as the basis for the instrument action levels | J22 Exposure Limits, Heat and Cold Stress |
Incident number; date; product or hazard; zones established (time); entry control point location; entry control officer (role). Per entry: team number; members (roles and IDs); PPE class; SCBA cylinder size and pressure at entry; time in; task; expected time out; time out; pressure at exit; pre-entry vitals (time, by whom); post-exit vitals; decon complete (time); exposure report filed (Y/N). Backup team: members, PPE, ready time. Full fields in Form - Hazmat Entry Log and Air Monitoring Record.
Instrument ID; bump test (date, time, result, by whom); last calibration date. Per reading: time; location (zone, floor, point); O2 %; LEL %; CO ppm; H2S ppm; HCN ppm; PID ppm; radiation (units); action level reached (Y/N); action taken; initials. Rehab area readings; overhaul readings; perimeter readings at battery incidents with the watch period start and end.
Member (role, ID); team assignment date; baseline medical evaluation (date; physician confirms complete, no content); periodic evaluation dates; exposure events (date, incident number, substance, route, duration, PPE, monitoring readings, decon, symptoms, post-exposure evaluation date); exit evaluation (date); record retention: career plus 30 years; copy provided to member (dates). Medical content stays with the physician; this record holds dates and events only.
| Step | Done | Time | By |
|---|---|---|---|
| Corridor location chosen: warm zone, upwind and uphill of the hot zone, downhill of the cold zone, water runoff controlled | |||
| Emergency decon ready (charged line, low pressure, fog) before the first entry | |||
| Corridor marked and one-way; entry control point at the hot-zone side | |||
| Station 1 tool and equipment drop (tarp, bins) | |||
| Station 2 gross wash (pool, hose, brushes, detergent as the product requires) | |||
| Station 3 suit wash and rinse (second pool) | |||
| Station 4 suit removal (bench or chair; bags labelled) | |||
| Station 5 SCBA removal (last, after the suit is clear of the face) | |||
| Station 6 inner glove and clothing removal; personal wash; towels, replacement clothing | |||
| Station 7 medical check and rehab handover; vitals recorded on the entry log | |||
| Decon team in PPE at the level the risk assessment set; decon team’s own decon planned | |||
| Air monitoring at the corridor | |||
| Contaminated water and waste containment arranged; disposal contact noted | |||
| Privacy, warmth and lighting for members and civilians | |||
| Corridor struck last; decon team decontaminated; equipment bagged for cleaning |
| Step | Done | Time |
|---|---|---|
| Dispatch confirmed EV, hybrid or battery involvement; inside a building? charging? | ||
| Approach from upwind; stage apparatus with a water supply plan (sustained large flow or burn-out decision) | ||
| Identify the vehicle (badges, charging port, rescue sheet, plate lookup) and the high-voltage system | ||
| Full PPE and SCBA for every member near the vehicle; off-gas is IDLH | ||
| Stabilize: park, off, key away, chock; high-voltage disconnect only where trained and the guide shows it | ||
| Thermal imager on the pack; air monitoring at the perimeter | ||
| Extinguish the cabin and ordinary vehicle fire; confine the battery; cool directly or let burn out with exposures protected | ||
| No penetration of the pack; no purchase points through the battery; charged line at any extrication | ||
| Isolate charging equipment at the source if the vehicle was charging | ||
| Watch period: thermal imager and monitoring until readings are stable for the period the SOG sets | ||
| Tow arranged; operator given the written stranded-energy and reignition warning; apparatus escort to the yard | ||
| Yard asked for the clear area (about 15 m or best achievable) from vehicles and structures | ||
| Handover recorded (who, when, what they were told); exposure reports filed; debrief done |
| Field | Entry |
|---|---|
| Site address, occupancy, owner and 24-hour technical contact | |
| System type and chemistry (lithium-ion NMC, LFP, other; flow battery; other) | |
| Capacity (kWh) and number of units or containers; location (indoor, outdoor, roof, container, garage) | |
| Associated solar PV, EV charging, generator | |
| Disconnects: AC, DC, emergency stop, location and who operates | |
| Fire protection: detection, suppression, gas detection, explosion control, ventilation | |
| Owner’s emergency response plan (required by the installation standard) attached, with date | |
| Access, water supply, setback from other structures | |
| Hazards to responders: gas accumulation and deflagration risk, stranded energy, high voltage, confined space inside containers, roof access | |
| Response plan: defensive default, no entry to gas-filled enclosure, ventilation decision basis, cooling plan, watch period, who takes over | |
| CAD flag entered (date); plan reviewed (date; annually) |
| Indicator | District A | District B | District C | Volunteer stations | Department | Last quarter | Target |
|---|---|---|---|---|---|---|---|
| Hazmat incidents above awareness (count) | |||||||
| Battery, EV, ESS, solar, hydrogen incidents (count) | |||||||
| Competency currency by level (%) | 100 | ||||||
| Instrument bump test readiness (% of sample) | 100 | ||||||
| Monitoring before entry (%) | 100 | ||||||
| Decon corridor checklist at entry incidents (%) | 100 | ||||||
| Exposure reports filed before end of shift (%) | 100 | ||||||
| EV and ESS handover documented (%) | 100 | ||||||
| Energy-hazard training currency (%) | 100 | ||||||
| Near-miss and good-catch reports (per 10 incidents); % acknowledged in 15 days | rising; 100 | ||||||
| Stop-work and challenge calls (count); % reviewed; reprisals | rising; 100; 0 | ||||||
| Members who can raise a concern (% agree, annual) | rising | ||||||
| Concerns raised / answered within 15 days | 100 | ||||||
| Exposures with symptoms (count) | falling | ||||||
| Battery reignitions after handover (count) | tracked | ||||||
| Corrective actions open / overdue | 0 overdue |
| Member (role, ID) | Awareness refresher | Operations practical evolution | Mission-specific (list) | Opioid scenario | Energy hazards session (guidance version) | Instrument sign-off (instrument IDs) | Technician recertification (if applicable) | WHMIS review |
|---|---|---|---|---|---|---|---|---|
Canadian Centre for Occupational Health and Safety [CCOHS]. (2018). Opioids (including fentanyl): Precautions for first responders (OSH Answers). https://ccohs.ca/oshanswers/hsprograms/fentanyl.html
Center for Public Safety Excellence [CPSE]. (2019). Fire and emergency service self-assessment manual (10th ed.). Commission on Fire Accreditation International. https://cpse.org/wp-content/uploads/2019/08/10th-Edition-FESSAM-Strikethrough-Underline-v.4.pdf
Conklin, T. (2012). Pre-accident investigations: An introduction to organizational safety. Ashgate.
Criminal Code, R.S.C. 1985, c. C-46 (Canada; consolidated to 2026-09-30; ss. 22.1, 22.2 and 217.1). https://laws-lois.justice.gc.ca/eng/acts/c-46/
CSA Group. (2011). CAN/CGSB/CSA-Z1610-11 (R2021), Protection of first responders from chemical, biological, radiological, and nuclear (CBRN) events. https://www.csagroup.org/store/product/CAN-CGSB-CSA-Z1610-11/
CSA Group. (2018). CAN/CSA-Z94.4-18 (R2023), Selection, use, and care of respirators (5th ed.). https://www.csagroup.org/store/product/2426374/
CSA Group. (2019). CSA Z180.1:19, Compressed breathing air and systems (6th ed.). https://www.csagroup.org/store/product/CSA%20Z180.1:19/
CSA Group. (2024). CSA Z462:24, Workplace electrical safety (6th ed.; based on NFPA 70E). https://www.csagroup.org/store/product/2431089/
Dekker, S. (2016). Just culture: Restoring trust and accountability in your organization (3rd ed.). CRC Press.
Edmondson, A. C. (1999). Psychological safety and learning behavior in work teams. Administrative Science Quarterly, 44(2), 350–383. doi:10.2307/2666999
Fire Safety Research Institute [FSRI]. (n.d.-a). Electric vehicle fire experiments [Urban Fire Forum presentation, 2025–2026]. UL Research Institutes. https://www.nfpa.org/-/media/Project/Storefront/Catalog/Files/Member-Sections/Metro-Chiefs/Urban-Fire-Forum/2026/ULRI-FSRI-UFF-Metro-Chiefs-EV-Experiments-UFF.pdf
Hazardous Products Act, R.S.C. 1985, c. H-3 (Canada; consolidation date not recorded). https://laws-lois.justice.gc.ca/eng/acts/h-3/
Hazardous Products Regulations, SOR/2015-17 (Canada; consolidation consulted in 2026, date not recorded; WHMIS 2015). https://laws-lois.justice.gc.ca/eng/regulations/SOR-2015-17/
Health Canada. (n.d.). Fentanyl exposure: Protection, treatment, myths and facts (adapted from U.S. Department of Homeland Security, 2017). https://cumming.ucalgary.ca/sites/default/files/teams/290/Fentanyl%20Exposure%20Protection%20Treatment%20Myths%20and%20Facts.pdf
Hollnagel, E. (2014). Safety-I and Safety-II: The past and future of safety management. Ashgate.
International Association of Fire Fighters [IAFF], UL Solutions, & Fire Safety Research Institute [FSRI]. (2023). Considerations for fire service response to residential battery energy storage system incidents. https://www.iaff.org/wp-content/uploads/IAFF_DOE_ResidentialESSConsiderations_Final.pdf
Marx, D. (2001). Patient safety and the “just culture”: A primer for health care executives. Columbia University.
National Fire Protection Association. (2022). NFPA 1891, Standard on selection, care, and maintenance of hazardous materials, CBRN, and emergency medical operations clothing and equipment (first edition). https://www.nfpa.org/codes-and-standards/nfpa-1891-standard-development/1891
National Fire Protection Association. (2022). NFPA 1990, Standard for protective ensembles for hazardous materials and CBRN operations (consolidates NFPA 1991, 1992 and 1994). https://www.nfpa.org/codes-and-standards/nfpa-1990-standard-development/1990
National Fire Protection Association. (2022). NFPA 470, Hazardous materials/weapons of mass destruction (WMD) standard for responders (consolidates NFPA 472, 473 and 1072). https://www.nfpa.org/codes-and-standards/nfpa-470-standard-development/470
National Fire Protection Association. (2023). NFPA 2, Hydrogen technologies code. https://www.nfpa.org/codes-and-standards/nfpa-2-standard-development/2
National Fire Protection Association. (2024). NFPA 1550, Standard for emergency responder health and safety (consolidates NFPA 1500, 1521 and 1561). https://www.nfpa.org/codes-and-standards/nfpa-1550-standard-development/1550
National Fire Protection Association. (2024). NFPA 1660, Standard for emergency, continuity, and crisis management: Preparedness, response, and recovery (consolidates NFPA 1600, 1616 and 1620). https://www.nfpa.org/codes-and-standards/nfpa-1660-standard-development/1660
National Fire Protection Association. (2025). NFPA 1580, Standard for emergency responder occupational health and wellness (consolidates NFPA 1581, 1582, 1583 and 1584). https://www.nfpa.org/codes-and-standards/nfpa-1580-standard-development/1580
National Fire Protection Association. (2026). NFPA 855, Standard for the installation of stationary energy storage systems. https://www.nfpa.org/codes-and-standards/nfpa-855-standard-development/855
National Transportation Safety Board [NTSB]. (2020). Safety risks to emergency responders from lithium-ion battery fires in electric vehicles (Safety Report NTSB/SR-20/01). https://www.ntsb.gov/safety/safety-studies/Documents/SR2001.pdf
Occupational Safety and Health Administration [OSHA]. (n.d.-a). Access to employee exposure and medical records (29 C.F.R. § 1910.1020). U.S. Department of Labor. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1020
Ontario Ministry of Labour, Immigration, Training and Skills Development [MLITSD]. (n.d.). Firefighter guidance notes (Section 21 Advisory Committee; individual notes revised to 2026). https://www.ontario.ca/document/firefighter-guidance-notes
Reason, J. (1997). Managing the risks of organizational accidents. Ashgate.
The Human Factor. (2026a). After the Call, Manual 02: The three tiers and event triage [Unpublished manuscript].
Transport Canada. (2024). 2024 Emergency response guidebook (with the U.S. Department of Transportation and the Secretariat of Infrastructure, Communications and Transportation of Mexico). https://tc.canada.ca/en/dangerous-goods/canutec/emergency-response-guidebook
Transportation of Dangerous Goods Act, 1992, S.C. 1992, c. 34 (Canada; consolidation date not recorded). https://laws-lois.justice.gc.ca/eng/acts/t-19.01/
Transportation of Dangerous Goods Regulations, SOR/2001-286 (Canada; consolidation consulted in 2026, date not recorded). https://laws-lois.justice.gc.ca/eng/regulations/SOR-2001-286/