Form - SCBA Inspection and Maintenance Log
Document FSSMS-FRM-15Stage 1Revision 4Version 0.3.3
Topic pages open on your jurisdiction, and requirements tables show its line. You can change this on any page.
One log per SCBA for its service life, kept by the SCBA technician in {{Records system}}. It holds the unit’s identity, its technician-level events (acceptance, annual flow test, repair, parts, upgrade, adverse condition, retirement) and a pointer to the daily and weekly user sheets, which live in SWP - SCBA Daily and After-Use Inspection and Cleaning. The record set is the one the care and maintenance standard expects for SCBA: inventory by serial, inspections, cleaning, maintenance and repairs with parts and test results, adverse-condition events, and retirement (NFPA 1850, 2026, ch. 14 and 17), and the maintenance records the respirator standard requires (CSA Z94.4-18, cl. 14).
| Field | Entry |
|---|---|
| SCBA serial number | |
| Manufacturer, model and configuration | |
| NIOSH approval (TC) number; NFPA 1970 edition certified; CBRN option (yes / no) | |
| Date of manufacture | |
| Date accepted into service; acceptance test reference | |
| Retirement date due (15 years from manufacture unless upgraded; about 20 years maximum) | |
| Assignment (apparatus / station / member / spare / RIT pack) | |
| Facepiece model(s) and sizes approved with this unit | |
| Cylinder model(s) approved with this unit | |
| Current status (in service / tagged out / quarantined / retired) |
| Date | Event type | Description and findings | Parts replaced (part number) | Test result (flow test, leak test, PASS, EOSTI, HUD) and breathing machine ID | Technician (name, authorization reference) | Returned to service (date, by) | Adverse-condition or corrective action reference |
|---|---|---|---|---|---|---|---|
Event types: acceptance test; annual flow and function test; leak test; repair; rebuild; software or electronics service; manufacturer upgrade kit; specialized cleaning; adverse condition (tag out, secure, chain of custody); recall or rescission check; retirement and rendering unusable.
| Field | Entry |
|---|---|
| Location of daily and weekly user sheets for this unit (station, binder or system path) | |
| Cylinder register entries for cylinders assigned to this unit | |
| Last reconciliation of this unit’s approval against the NIOSH Certified Equipment List (date, by) |
| Field | Type | Required | Who completes |
|---|---|---|---|
| SCBA serial number | Text, unique | Yes | Technician at acceptance |
| Manufacturer, model, configuration | Text | Yes | Technician |
| NIOSH approval number; NFPA 1970 edition; CBRN option | Text; text; yes / no | Yes | Technician, from the label and the fleet approval register |
| Date of manufacture | Date | Yes | Technician |
| Date accepted; acceptance test reference | Date; text | Yes | Technician |
| Retirement date due | Date | Yes | Program administrator |
| Assignment | Choice plus text | Yes; updated on change | Program administrator |
| Facepiece and cylinder models approved | Text | Yes | Technician |
| Current status | Single choice | Yes; updated on change | Technician or program administrator |
| Event date | Date | Yes per event | Technician |
| Event type | Single choice from list | Yes per event | Technician |
| Description and findings | Text | Yes per event | Technician |
| Parts replaced | Text with part numbers | Yes if any | Technician |
| Test result and breathing machine ID | Pass / fail with values; text | Yes for any test event | Technician |
| Technician name and authorization reference | Text | Yes per event | Technician |
| Returned to service | Date; name | Yes per event that took the unit out of service | Technician |
| Adverse-condition or corrective action reference | Text | Yes if the event arose from one | Technician; HSO confirms |
| Pointers (user sheets, cylinder register, CEL reconciliation) | Text; date | Yes | Program administrator |
Retention. Life of the unit plus five years (05 Document Control and Records). Audit use. The auditor samples three units and checks: an annual flow test inside 12 months; every tag-out event has a return-to-service entry or a retirement entry; every adverse condition has a corrective action reference; the retirement date has not passed.
CSA Group. (2018). CAN/CSA-Z94.4-18 (R2023), Selection, use, and care of respirators (5th ed.). https://www.csagroup.org/store/product/2426374/
National Fire Protection Association. (2026). NFPA 1850, Standard on selection, care, and maintenance of protective ensembles for structural and proximity firefighting and open-circuit self-contained breathing apparatus (SCBA) (consolidates NFPA 1851 and 1852). https://www.nfpa.org/codes-and-standards/nfpa-1850-standard-development/1850