Skip to content
 

Form

Form - Workplace Inspection Checklist (Station)

Document FSSMS-FRM-36Stage 1Revision 4Version 0.3.3

Topic pages open on your jurisdiction, and requirements tables show its line. You can change this on any page.

How to use

Monthly, by the station officer with a worker member; a JOHSC member joins at least once a year per station and on the quarterly sample (02 JOHSC Integration section 5.9). Walk every area in the order below. Mark each line OK, Deficient or N/A. Every Deficient line gets a note, a photograph where useful, and a decision: fixed on the spot, work order raised, or entered in the Corrective Action Register with a priority. Before starting, read the last three months’ forms and check whether their deficiencies were actioned; record the answer in Part A. Finish with a five-minute conversation with the crew (Part D). The whole workplace, including grounds, outbuildings and any shared premises, is covered within 12 months; the “areas not covered this month” line in Part A keeps that honest.

The health and safety standard expects facility inspections and provides sample facility inspector checklists (NFPA 1550, 2024, ch. 12 and Annex K). The applicable OHS statute may require regular inspection procedures and schedules as part of the hazard identification system, and may fix how often the committee or representative inspects (J04 Hazard Assessment and Workplace Inspections). This form is The Human Factor’s own synthesis for a fire station.

Part A: Header

Field Entry
Station
Date and start time
Inspected by (role) Station officer: / Worker member: / JOHSC member (if present):
Platoon or volunteer company
Previous three months’ forms reviewed? Deficiencies actioned? Y / N; notes:
Areas not covered this month (and when they will be)
Total lines deficient
Items fixed on the spot / work orders raised / register entries / /

Part B: Checklist by area

B1. Exterior, grounds and access

# Item OK Def. N/A Note
1 Apparatus apron, ramps and walkways free of ice, snow, debris, trip hazards; drainage working
2 Exterior lighting working; building number visible
3 Fuel storage, propane and generator: secured, labelled, no leaks, propane outdoors, clearances kept
4 Flammable and combustible waste storage outdoors in closed containers
5 Hydrant, standpipe or static water supply on site accessible
6 Site security: fences, gates, cameras, doors lock; after-hours access controlled
7 Smoking area, if any, outside and away from doors and fuel
8 Backup generator tested per schedule; transfer switch labelled; log present

B2. Apparatus bay

# Item OK Def. N/A Note
9 Diesel exhaust capture connected to every apparatus and working; hoses and nozzles undamaged; fan runs
10 Bay doors: safety edges reverse on contact; photo eyes work; manual release accessible; door tracks clear
11 Floor: clean, dry, free of oil; drains clear; no trip hazards; traffic lines visible
12 Vehicle exhaust interlocks and carbon monoxide detection working, if fitted
13 Contamination zoning marked: red (bay), yellow (transition and decon), green (living); turnout gear not in green areas
14 Turnout gear storage: ventilated, out of direct sunlight, away from diesel exhaust and living areas; no gear in cabs or dorms
15 Decontamination area: gross decon station, wipes, bags, shower within reach, signage; supplies stocked
16 Gear extractor and dryer: operating instructions posted, logbook current, detergent correct, trained operators listed
17 SCBA storage and fill station: cylinders secured, air quality certificate current and posted, fill station log, compressor service current
18 Compressed gas cylinders (all types) secured upright, capped, segregated by type
19 Hose tower or drying rack: fall protection, guardrails, access secured
20 Ladders (portable, for building use) in good condition, rated, stored
21 Pits, trenches and floor openings covered, guarded, signed
22 Machine guarding on grinders, saws, compressors, pumps; lockout points identified
23 Electrical: panels accessible with 1 m clearance, labelled, closed; no damaged cords; no daisy-chained power bars; outdoor and wet-area outlets GFCI
24 Battery charging stations ventilated, no corrosion, eyewash nearby
25 Housekeeping: storage racks stable and loaded within rating; no storage within exit width; aisles clear
26 Spill kit present and stocked

B3. Shop, storage and mechanical rooms

# Item OK Def. N/A Note
27 Flammable liquids in an approved cabinet; quantities within limits; cabinet closed and grounded
28 WHMIS: all containers labelled; SDS available for every product (station list matches shelf) and current as the WHMIS regulation requires
29 Eye protection, hearing protection, gloves available at the task; eyewash station accessible, flushed per schedule, dated
30 Lockout kit available; lockout procedure posted for shop equipment
31 Mechanical, electrical and boiler rooms: no storage, no moisture, no mould, clearances kept, doors closed and locked where required
32 Ventilation in shop and storage working; no odours of fuel or solvent
33 Pressure vessels (air receivers, hot water) certified; relief valves tagged

B4. Living, kitchen, dormitory and office areas

# Item OK Def. N/A Note
34 Green zone kept clean of turnout gear, SCBA, contaminated tools and boots
35 Kitchen: fire separation door self-closing and latching; range hood and suppression inspected and tagged; extinguisher present; no grease build-up
36 Food storage temperatures; cleanliness; pest control
37 Dormitory: smoke alarms working; egress clear; adequate separation and ventilation; lighting and noise reasonable for rest
38 Fitness area: equipment in good repair, inspected, instructions posted; floor and clearances; AED nearby
39 Washrooms and showers: clean, hot water, ventilation, non-slip surfaces; shower available within the hour of return from a fire
40 Laundry: station wear laundered separately from turnout gear; machines maintained
41 Office ergonomics: chairs, monitors, lighting; cords managed
42 Indoor air: no visible mould, water staining or persistent odour; humidity reasonable; filters changed per schedule
43 Heating and cooling working; thermostats functional

B5. Life safety and emergency equipment

# Item OK Def. N/A Note
44 Exits: unobstructed, doors open freely, signed, exit lights working, no storage in exit passages, full width kept
45 Emergency lighting monthly function test done and logged
46 Fire alarm, detection and sprinkler (if fitted) inspected and tagged; no obstructions to heads; valves open and supervised
47 Portable extinguishers: present at marked locations, charged, tagged, monthly check initialled, mounted
48 Station fire safety and evacuation plan posted; assembly point signed; last drill date within 12 months
49 First aid kit: contents complete per the regulation, in date, location signed; first aider list current
50 AED: indicator green, pads and battery in date, location signed, monthly check logged
51 Eyewash and emergency shower where required: accessible, flushed weekly, dated
52 Carbon monoxide alarms in living areas working and in date

B6. Communications, information and records

# Item OK Def. N/A Note
53 Station radio and alerting working; backup power tested
54 Safety board: OHS policy posted; JOHSC minutes within 10 days; member names of JOHSC posted; emergency numbers; the applicable statute available; change notices within 30 days
55 Point-of-use OGs, SWPs and job aids match the controlled version (spot check three)
56 Hazard, near-miss and good-catch report forms (or the digital route) available and known to the crew
57 Apparatus daily and weekly check sheets complete for the month; SCBA check sheets complete; exceptions actioned
58 Extractor log, air quality certificate, AED and first aid logs current (cross-check)

B7. Apparatus (parked, walk-around; the daily check covers function)

# Item OK Def. N/A Note
59 Cab clean of contaminated gear; seat belts present and functional; SCBA seat brackets secure
60 Equipment secured in compartments; no loose tools in cab; manifest present
61 Steps, handrails and standing surfaces slip-resistant and intact; fall-from-apparatus controls present
62 Wheel chocks, cones, high-visibility vests on board; roadway scene kit complete
63 PPE on board for every riding position; second hoods and decon bags stocked

B8. Training ground and outbuildings (if on site)

# Item OK Def. N/A Note
64 Tower and props: pre-use checklist in use; engineered inspection within 12 months; anchors tagged; access controlled
65 Burn building: condition, instrumentation if fitted, fuel storage, last inspection
66 Outbuildings: structural condition, lighting, storage, pests, access

Part C: Deficiencies and actions

# (line) Deficiency Photo? Priority (P1 to P4) Action Fixed on spot / Work order no. / Register ID Owner (role) Due

Priority is the department’s one scale, the same one the Corrective Action Register uses for every deficiency. P1 (Imminent): interim control immediately, the same shift, with the fire chief and JOHSC co-chairs told within 24 hours; plan due in two working days; closed within seven days. P2 (Serious): interim control within 24 hours where practicable; plan due in seven days; closed within 30 days. P3 (Moderate): plan due in 30 days; closed within 90 days. P4 (Improvement): plan by the next quarterly program update; closed within 365 days or the next budget cycle. Extensions and escalation follow the register. Any P1 is also reported to the district chief and the HSO before the inspection team leaves the station.

Part D: Conversation with the crew

Five minutes with whoever is on duty or at the training night. Record roles, not names.

Question What was said (summary)
What is the one thing in this station you would fix first?
Has anyone raised a concern here in the last three months, and did they hear back?
Is there anything about how we do decon, gear care or SCBA checks here that the procedure does not match?
Anything else?

Part E: Sign-off

Role Signature or system confirmation Date
Station officer
Worker member
JOHSC member (if present)
District chief (reviewed)
Entered in {{Records system}} by

Fields

Field Type Required Who completes
Station Pick list Yes Station officer
Date and start time Date-time Yes Station officer
Inspected by (roles) Text, three slots Yes Station officer
Platoon or company Pick list Yes Station officer
Previous forms reviewed and actioned Y/N plus text Yes Station officer
Areas not covered this month Text Yes (may be “none”) Station officer
Lines 1 to 66 OK / Deficient / N/A each with note Yes Inspection team
Photo attachments File Where useful Inspection team
Part C rows Line ref., text, priority, action, disposition, owner role, due date One per deficient line Inspection team; HSO confirms priority
Part D answers Text, four slots Yes Inspection team
Totals (deficient, fixed, work orders, register entries) Integer Yes Station officer
Sign-off Signatures or system confirmation, dates Yes Roles listed
Entered in records system Role, date Yes Station officer or delegate

Jurisdiction requirements

This chapter relies on the following legal requirements, which differ by province and territory. Check your jurisdiction’s section on each topic page before adopting it.

Topic What to check in your jurisdiction Page
Hazard Assessment and Workplace Inspections Whether the OHS program must include regular inspection procedures and schedules, and whether the law fixes how often the workplace is inspected and by whom (the monthly cadence here is this program’s own schedule) J04 Hazard Assessment and Workplace Inspections
Joint Committee and Health and Safety Representative The committee’s or representative’s role in workplace inspections, and what must be posted, such as committee minutes and member names (line 54) J05 Joint Committee and Health and Safety Representative
Records Retention How long inspection records must be kept J09 Records Retention
Stations, Premises and Building Codes The fire code and building rules that govern flammable liquid storage, exits, emergency lighting and fire protection systems in stations (lines 27 and 44 to 48) J20 Stations, Premises and Building Codes
WHMIS, Hazardous Materials and Asbestos The workplace WHMIS regulation (labels, safety data sheets and their currency, worker education) and any spill reporting rule (lines 26 and 28) J21 WHMIS, Hazardous Materials and Asbestos
First Aid First aid kit contents, first aider certification and numbers per station and shift, and any first aid record requirement (line 49) J24 First Aid

References

National Fire Protection Association. (2024). NFPA 1550, Standard for emergency responder health and safety (consolidates NFPA 1500, 1521 and 1561). https://www.nfpa.org/codes-and-standards/nfpa-1550-standard-development/1550

© 2026 The Human Factor · Licensed under CC BY-NC-SA 4.0 with the Adopting Agency Grant

General information only, not legal, medical or other professional advice. Verify every requirement against the current official text of the law, standards and manufacturer instructions that apply to you. Obtain your own legal review and consult your joint health and safety committee before adopting anything. You adopt, adapt, implement and rely on this material entirely at your own risk and on your own responsibility. Full terms: Terms of Use, thehumanfactor.ca.